1,530 research outputs found
Coherently Dedispersed Polarimetry of Millisecond Pulsars
We present a large sample of high-precision, coherently-dedispersed
polarization profiles of millisecond pulsars (MSPs) at frequencies between 410
and 1414 MHz. These data include the first polarimetric observations of several
of the pulsars, and the first low-frequency polarization profiles for others.
Our observations support previous suggestions that the pulse shapes and
polarimetry of MSPs are more complex than those of their slower relatives. An
immediate conclusion is that polarimetry-based classification schemes proposed
for young pulsars are of only limited use when applied to millisecond pulsars.Comment: 28 pages, 10 figures. Text matches version that appeared in ApJS.
Full paper with high-resolution figures available at
ftp://ftp.jb.man.ac.uk/pub/psr/papers/msppolpton.ps.g
First-principles prediction of redox potentials in transition-metal compounds with LDA+U
First-principles calculations within the Local Density Approximation (LDA) or
Generalized Gradient Approximation (GGA), though very successful, are known to
underestimate redox potentials, such as those at which lithium intercalates in
transition metal compounds. We argue that this inaccuracy is related to the
lack of cancellation of electron self-interaction errors in LDA/GGA and can be
improved by using the DFT+ method with a self-consistent evaluation of the
parameter. We show that, using this approach, the experimental lithium
intercalation voltages of a number of transition metal compounds, including the
olivine LiMPO (M=Mn, Fe Co, Ni), layered LiMO (Co,
Ni) and spinel-like LiMO (M=Mn, Co), can be reproduced
accurately.Comment: 19 pages, 6 figures, Phys. Rev. B 70, 235121 (2004
Technical Design Report for PANDA Electromagnetic Calorimeter (EMC)
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the
PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment. The performance figures are based on extensive prototype tests and radiation hardness studies. The document shows that the EMC is ready for construction up to the front-end electronics interface
Technical Design Report for the PANDA Micro Vertex Detector
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is
outlined
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It
shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible
modifications arising during this process
Physics Performance Report for PANDA Strong Interaction Studies with Antiprotons
To study fundamental questions of hadron and nuclear physics in interactions of antiprotons with nucleons and nuclei, the universal PANDA detector will be build. Gluonic excitations, the physics of strange and charm quarks and nucleon structure studies will be performed with unprecedented accuracy thereby allowing high-precision tests of the strong interaction. The proposed PANDA detector is a state-of-the-art internal target detector at the HESR at FAIR allowing the detection and identifcation of neutral and charged particles generated within the relevant angular and energy range. This report presents a summary of the physics accessible at PANDA and what performance can be expected
ICEAGE (Incidence of Complications following Emergency Abdominal surgery: Get Exercising): study protocol of a pragmatic, multicentre, randomised controlled trial testing physiotherapy for the prevention of complications and improved physical recovery after emergency abdominal surgery
WHODAS. World Health Organisation disability assessment scale. (PDF 24 kb
The HPS electromagnetic calorimeter
The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called “heavy photon.” Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HPS experiment is installed in Hall-B of Jefferson Lab. This article presents the design and performance of one of the two detectors of the experiment, the electromagnetic calorimeter, during the runs performed in 2015–2016. The calorimeter's main purpose is to provide a fast trigger and reduce the copious background from electromagnetic processes through matching with a tracking detector. The detector is a homogeneous calorimeter, made of 442 lead-tungstate (PbWO4) scintillating crystals, each read out by an avalanche photodiode coupled to a custom trans-impedance amplifier
- …